Firefighter Fire-Entry Suit F-22
The firefighter fire-entry suit is protective clothing worn by firefighters for short-time passage through a fire zone, or for a short entry into a fire scene for firefighting.
Key parameters
- Outer shell flame retardancy - damaged length, warp and weft: ≤ 25 mm
- Outer shell flame retardancy - afterflame time: ≤ 1 s
- Outer shell flame retardancy - afterglow time: ≤ 25 s
- Outer shell tear strength, warp and weft: ≥ 180 N
- Outer shell breaking strength, warp and weft: ≥ 1300 N
- Outer shell thermal stability - dimensional change, warp and weft: ≤ 3 %
- Outer shell hydrostatic pressure resistance: 220 kPa
- Radiant heat penetration resistance (time for the inner surface to rise 24 °C): > 75 s
- Visor light transmittance: > 85 %
- Flame and radiant heat protection (TPP): > 40 cal/cm²
- Seam breaking strength: ≥ 650 N
- Flame temperature resistance (short-time exposure): 1000 °C
Overview
The firefighter fire-entry suit is protective clothing worn by firefighters for short-time passage through a fire zone, or for a short entry into a fire scene for firefighting and rescue work. The garment is built up from several material layers - refractory, fire-retardant, insulation, waterproof and vapour-barrier layers - and provides good fire resistance and thermal insulation. It is intended as personal protective equipment for firefighters working in the flame zone.